Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.9685274

- Product Categories
- Friendly Links
- home > Supply > Supply of 24 electrostatic generator installation | Shandong electrostatic generator prices
Information Name: | Supply of 24 electrostatic generator installation | Shandong electrostatic generator prices |
Published: | 2013-08-02 |
Validity: | 30 |
Specifications: | |
Quantity: | 45.00 |
Price Description: | |
Detailed Product Description: | BSBY_f009 anti-static access control brand [Shunguan] The factory adhering to the "quality of life, service is the key, faith is fundamental," the purpose of the trip will continue anti-static equipment enterprises to solve any difficulties encountered. Electrostatic generator (ion emitter) is a special equipment to produce static electricity. Has a simple installation, smooth, static range of features. Electrostatic generator installation: 1, the DC high voltage supply is fixed in place. 2, the electrostatic emitter (Stick) based on the actual need to install fixed. 3, with a separate ground wire connected to the high voltage supply grounding screw on the back. 4, the electrostatic emitter (bar) high-pressure plug into the DC high voltage supply output jack (two holes and let it choose one), and comes with a plug lock nut. 5, confirm the power supply (mains) and DC high voltage supply line after the high-voltage power supply plug into a grounded mains outlet. 6, the DC supply power switch in the ON position, switch indicator light. 7, the band switch in the "1" position (or 2,3,4 position can be), the red indicator light, the output voltage display "0", the DC high voltage supply to enter the standby status. 8, the DC high voltage supply direct control on the front panel: Press the start button (START UP), and maintained for about 3 seconds. High supply trigger the start, the red light is off, the green light is on, the high voltage output value reached and exceeded undervoltage, high pressure supply to enter the self-locking state, you can release the start button. If you want to quit working (stop high-voltage output), as long as the power switch in the "OFF" position. 9, by another host control DC high voltage supply work. The host must provide two voltage greater than 24V, allows current greater than 1mA normally open contacts. If you touch switch or micro switch or PLC soft contacts or relays hard contacts. Through the "D" type connector stick to the high pressure supply of "D" type socket. 4,5 socket termination stop contact. 6,7 endpoint connection start contacts. Starts, the contacts 6,7 communication hold time for about 3 seconds. The high-voltage supply trigger the start. Then the green light is on, the red light goes out. High voltage supply output pressure and self-locking. When the high voltage supply to enter the self-locking state should withdraw from 6,7 contacts connected, otherwise the high pressure supply can not play short-circuit protection. If the high voltage supply to stop working, as long as the 4,5-side connectivity and keep for about 5 seconds, the green light is off, the red light is on. High supply back to standby status. Here in particular is connected 6,7 and 4,5 boot contacts should not stop contacts with self-locking switch or touch micro switch, which was connected by hand hold, let go automatically after homing or disconnected. If you want to monitor the working status of high-voltage supply, the status of their work on the host through the sound (or light) alarm. The host must provide less than 220V power and with the power to match the indicating device or alarm devices (such as red, green or buzzer). Socket 1,2 points normally closed contact, namely high pressure supply is working properly, the output pressure when the two contacts open. These two points can be considered connected to the red and buzzer. 2,3 for the normally open contacts, namely high pressure supply is working properly, the output pressure when the two contacts are closed, these two points can be considered received the green light. Users can set their own 1,2,3 contacts feature light or sound prompts (alarm). 10, the output voltage value adjustment: hand rotating band switch voltage regulator, the output voltage to a voltage value suitable for use. Dongguan Shun crown strict compliance with anti-static Equipment Co., Ltd.: Quality first, credit first, customer first purpose BSBY network marketing ...... |
Admin>>>
You are the 14866 visitor
Copyright © GuangDong ICP No. 10089450, [Ion air gun] Dongguan Shun crown Antistatic Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 14866 visitor
Copyright © GuangDong ICP No. 10089450, [Ion air gun] Dongguan Shun crown Antistatic Equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility